If you notice that your Miro humidifier isn't producing mist as expected, here are some steps to help diagnose and resolve the issue:

  1. Check Mist Formation:

    • If the humidifier engine's vibrator isn't forming mist, the fan may stop to prevent idle spinning. This indicates the water sensor has detected a lack of water, and the humidifier will shut down as a safety measure, activating the low water alert.

      • Ensure there's at least 1/3 of the water tank filled and restart the humidifier.

      • Reinstall the humidifier engine correctly. If this doesn't work, consider replacing the humidifier engine.

      • Regular cleaning of the humidifier engine is necessary. If any scale or debris is preventing mist formation, gently clean the vibrator with a soft sponge and neutral detergent, then reinstall.

      • If the vibrator surface is dirty, damaged, or broken and mist isn't forming, you may need to replace the humidifier engine.

  2. Fan Operation Check:

    • Even if mist is forming, the humidifier won't work if the fan isn't spinning.

      • Verify that the fan is correctly installed, remove and then reinstall the humidifier engine if necessary. Incorrect installation can cause temporary fan inoperation.

      • If the humidifier hasn't been used for a while, soak the engine in lukewarm water for about 30 minutes, manually spin the fan, then reinstall and try again. If mist forms but the fan still doesn't spin, the engine might be worn out or damaged and may need to be replaced.

  3. Water Level Check:

    • As a floating-type product, the vibrator needs a water depth of about 2.5cm to operate correctly. If the water is too low, the device will safely shut down. Simply refill the water to the appropriate level.

  4. "Inner Funnel" Component Installation Check:

    • Ensure the "inner funnel" component is installed. Without it, mist may form but will not be expelled upwards, remaining inside the humidifier like fog. Installing the tube allows mist to be expelled correctly.

  5. Check for Water in the "Floating Base":

    • The floating design of the Miro humidifier requires the lower body to maintain a water depth of about 2.5cm. If water has entered the interior of the lower body, it can sink below the normal level, causing the engine to descend too deep and prevent proper mist formation.

      • For models where the floating base isn't detachable (CP02, CP03, NR02, NR05, NR07, NR07S, NR07B, NR07G, NR08, NR08M, NR07SR, NR07BR, NR07GR), you may need to replace the floating base.

  6. Use of Genuine Miro Adapter Check:

    • Using a non-genuine adapter can cause the humidifier to receive power but not function correctly. Ensure you are using the genuine adapter that matches your model's specifications.